ACTISENSE PRO MUX-1

The Actisense® PRO-MUX-1 is a highly flexible platform that cures many interconnectivity headaches.

Reliable and robust, it provides industry leading isolation on all inputs and outputs as standard, so that connected devices safely avoid hazardous ground loops, the number 1 cause of product failure in NMEA 0183 networks.

Description

Features

  • 8 OPTO-isolated NMEA 0183 inputs
  • 6 ISO-Drive NMEA 0183 outputs
  • Bi-directional isolated serial port (can be used for additional NMEA 0183 input/ output)
  • Ethernet port
  • Alarm output (N/O and N/C contacts)
  • Designed for 12- and 24-Volt supply
  • Isolation to battery supply
  • Configurable input and output baud rates for rate conversion
  • Data combining from any input to any output
  • 2 independent Autoswitch virtual inputs with priority
  • Advanced sentence-based filtering / routing
  • Diagnostic LEDs on all inputs and outputs
  • Alarm, mode and Bi-colour Status LED’s
  • 2-part pluggable connector system supports both screw and screwless terminals
  • DIN rail or Panel mountable
  • Advanced statistics are available via a Web Browser

SPECIFICATION

Technical Specification

Power Supply
Input supply voltage 9 to 35 V DC
Input supply current 250mA max @ 12V DC (all outputs @ full drive into 100 ohm loads)
Input protection Continuous reverse polarity, transient overvoltage and ESD protection
Power indicator LED, Blue – indicates unit is functioning correctly
NMEA 0183 Port – Listener & Talker
Number of Listener / input ports 8 isolated NMEA 0183 Listeners
Number of Talker / output ports 6 isolated NMEA 0183 Talkers
Compatibility Fully NMEA 0183, RS422 & RS232 compatible. RS485 Listener compatible
Electrical isolation 2500 V input to ground, 1500 V output to ground using ISO-Drive™
Speed / baud rate In1 to In4: up to 38400 bps In5 to In8: 4800 bps Out1: up to 115200 bps Out2 to Out6: up to 38400 bps
Talker output voltage drive >= 2.1V (differential) into 100 ohm
Talker output current drive 20 mA maximum per output
Talker output protection Short circuit and ESD
Listener input voltage tolerance -15 V to +15 V continuous, -35 V to +35 V short term (< 1 second)
Listener input protection Current limited, overdrive protection to 40 VDC and ESD protection
Listener data indicator LED, Green (Flashes to indicate valid input)
Talker data indicator LED, Orange (Flashes at data rate)
Status indicator LED, Green / Yellow / Red to indicate status (see user manual)
Serial Port
Number of input ports 1 isolated input
Number of output ports 1 isolated output
Compatibility RS422 & RS232 compatible. RS485 Listener compatible
Electrical isolation 2500 V input to ground 1500 V output to ground using ISO-Drive™
Speed / baud rate 115200 bps
Output voltage drive >= 2.1V (differential) into 100 ohm
Output current drive 20 mA max.
Output protection Short circuit and ESD
Input voltage tolerance -15 V to +15 V continuous, -35 V to +35 V short term (< 1 second)
Input protection Current limited, overdrive protection to 40 VDC and ESD protection
Ethernet Port
Host interface 10/100BaseT, automatic polarity detection
Supported protocols TCP/IP for configuration and firmware updating. NMEA 0183 over Ethernet coming as a future update
Connector RJ45
Electrical isolation 2kV
Indicators Green – Link, Yellow – 100 Mbps
Mode Inputs
Input voltage range 0 to 35V DC
Protection Transient overvoltage and ESD protection
Alarm Output
Contacts Normally open and normally closed
Electrical isolation 1000V between power supply and contacts
Alarm indicator LED, red indicates a valid alarm condition
Mechanical
Housing material Polycarbonate / ABS blend
Flame retardancy UL94 – V0
Weight 270g including all screw plugs & shield screw
Mounting DIN rail mount (35mm top hat rail EN 50 022)
Compass safe distance 250mm
Wiring terminals Pluggable 2/3 way screw or screwless connectors, 5mm pitch, 12 to 30 AWG
Approvals and Certifications
EMC IEC 60945 (sections 9, 10 & 11)
CE 2014/30/EU
Environmental protection IP43
Operating temperature -15°C to +55°C
Storage temperature -40°C to +85°C
Relative Humidity (RH) 0 – 80% RH
Guarantee 5 years

GEEK MODE

  • Ethernet port – for configuration and diagnostics. Sharing NMEA 0183 data will be added in a future firmware update
  • 8 OPTO-Isolated NMEA 0183 inputs
  • 6 ISO-Drive NMEA 0183 outputs
  • Advanced Data Filtering/Routing
  • Configurable Input and output baud rates
  • Serial port – for configuration, diagnostics or as an additional NMEA 0183 input/output.
  • Free firmware updates make the device future-proof
  • Alarm output relay (N/O and N/C contacts available)
  • Mode inputs to provide manual selection of operational mode
  • Diagnostic LEDs on all inputs and outputs
  • Alarm status LED
  • Mode LED
  • Bi-colour status LED
  • DIN rail or Panel mountable
  • Pluggable connectors for quick and easy installation

Deprecated: explode(): Passing null to parameter #2 ($string) of type string is deprecated in /home3/betaemar/public_html/wp-content/plugins/woocommerce/includes/data-stores/class-wc-product-data-store-cpt.php on line 371

Deprecated: explode(): Passing null to parameter #2 ($string) of type string is deprecated in /home3/betaemar/public_html/wp-content/plugins/woocommerce/includes/data-stores/class-wc-product-data-store-cpt.php on line 371

Deprecated: explode(): Passing null to parameter #2 ($string) of type string is deprecated in /home3/betaemar/public_html/wp-content/plugins/woocommerce/includes/data-stores/class-wc-product-data-store-cpt.php on line 371

Deprecated: explode(): Passing null to parameter #2 ($string) of type string is deprecated in /home3/betaemar/public_html/wp-content/plugins/woocommerce/includes/data-stores/class-wc-product-data-store-cpt.php on line 371