SPECIFICATION
Supply (“BATT”) | ||
Voltage | 8-35 V | |
Current | 40 mA max @ 12V DC under no load | |
Supply (USB) | ||
Supply voltage | 4.75-5.25 V | |
Supply current from USB (see note 1) | 75 mA max | |
Opto-isolated Flexible Input | ||
Input voltage between +/- | Logical ‘1’/stop bit | -15-0.5 V |
Logical ‘0’/start bit | 4-15 V | |
Input current | Maximum is under +35v overload condition, Min @ 2.0v input level | 1.6-9 mA |
Differential input voltage | Required level for NMEA to be detected | 1.8-2 V |
Galvanic isolation | Between input & output | 2500 V |
Overdrive protection | 40 V | |
Input Baud rate (ports 0 & 1 + USB) | Configurable Baud rate | 4800-115200 bps |
Input Baud rate (ports 2 & 3) | Configurable Baud rate | 4800-57600 bps |
Input Baud rate (port 4) | Fixed Baud rate | 4800 bps |
ISO-Drive Flexible Output | ||
Output voltage between ISO Out +/A and ISO Out -/B (under no load) | Logical ‘1’ | -4.6 to -5 V |
Logical ‘0’ | 4.6-5 V | |
Output current at max load of 100 ohm | At maximum load, differential drive voltage reduces to 2.1v | 21 mA |
Output short circuit current (note 2) | Due to short circuit protection | 50-55 mA |
Galvanic isolation | From Opto input and (USB) ground | 1500 V |
Output Baud rate (ports 0 & 1 + USB) | Configurable Baud rate | 4800-115200 bps |
Data propagation delay | Under no-overload conditions | 1-100 ms |
General | ||
Ambient temperature | -20-70 °C | |
Guarantee | Extended Actisense guarantee | 3 Year |
Gland clamping range | Cable diameters accommodated | 4.5-10 mm |
IP Rating | IP66 |